Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
China Occupational Medicine ; (6): 476-480, 2021.
Article in Chinese | WPRIM | ID: wpr-923222

ABSTRACT

OBJECTIVE: To analyze the abnormal results and their causes of personal dose monitoring on medical radiation workers.METHODS: The medical radiation workers monitored from 2016 to 2019 in the personal dose monitoring room of Guangdong Province Hospital for Occupational Disease Prevention and Treatment were selected as the study subjects using convenient sampling method. The abnormal results and their causes of the medical radiation workers with personal dose equivalent ≥1.25 mSv(investigation level) in a single period were analyzed. RESULTS: The rate of abnormal results of personal dose monitoring was 0.26%(263/102 284). The false result rate was 0.19%(194/102 284), and that of the true result rate was 0.07%(69/102 284). A total of 73.38%(193/263) of medical radiation workers had abnormal results with an personal dose equivalent less than 5.00 mSv. Among different occupational groups, the abnormal results and false results in personal dose monitoring in interventional radiology group were the highest(all P<0.01). The abnormal result rate and false result rate were higher in the Pearl River Delta area than that in the non-Pearl River Delta area(0.27% vs 0.17%, 0.20% vs 0.12%, all P<0.05). The rate of false result of personal dose monitoring in the tertiary hospitals was lower than that in the non-tertiary hospitals(0.18% vs 0.30%, P<0.05). The main reason for the true results of personal dose monitoring was the increase of workload(43.48%), and the main reason for the false results was that the dosimeter was left in the workplace(57.73%). CONCLUSION: The rate of abnormal results of personal dose monitoring in the medical radiation workers is high. Radiological protection should be strengthened with emphasis on medical radiation workers in interventional radiology, Pearl River Delta area hospitals and non-tertiary hospitals.

2.
Journal of Third Military Medical University ; (24): 143-145, 2001.
Article in Chinese | WPRIM | ID: wpr-736918

ABSTRACT

Objective To explore the effects of hypoxia on the syntheses and secretion of adrenomedullin (AM), calcitonin gene related peptide (CGRP) and c-type natriuretic peptide (CNP) and the relationship between these peptides. Methods Rat models were established with hypoxia for 10, 20 and 30 d respectively and rats under normal altitude were served as control. Pulmonary artery pressure and the maximum increasing speed of right ventricle (RVdp/dtmax) were measured in every group. The dynamic changes of AM, CGRP and CNP concentrations in plasma were studied with radioimmunoassay. Results During hypoxia, pulmonary artery pressure and RVdp/dtmax were enhanced. Plasma AM and CNP concentrations were increased while CGRP was decreased significantly. The plasma level of AM had positive correlation with that of CNP, but negatively correlated with that of CGRP. Conclusion Results indicate that hypoxia may cause pulmonary artery pressure change and right ventricle has compensatory reaction to hypoxic pulmonary hypertension. Dynamic changes of plasma AM, CGRP and CNP concentrations can be regarded as indexes for condition of illness.

3.
Journal of Third Military Medical University ; (24): 143-145, 2001.
Article in Chinese | WPRIM | ID: wpr-735450

ABSTRACT

Objective To explore the effects of hypoxia on the syntheses and secretion of adrenomedullin (AM), calcitonin gene related peptide (CGRP) and c-type natriuretic peptide (CNP) and the relationship between these peptides. Methods Rat models were established with hypoxia for 10, 20 and 30 d respectively and rats under normal altitude were served as control. Pulmonary artery pressure and the maximum increasing speed of right ventricle (RVdp/dtmax) were measured in every group. The dynamic changes of AM, CGRP and CNP concentrations in plasma were studied with radioimmunoassay. Results During hypoxia, pulmonary artery pressure and RVdp/dtmax were enhanced. Plasma AM and CNP concentrations were increased while CGRP was decreased significantly. The plasma level of AM had positive correlation with that of CNP, but negatively correlated with that of CGRP. Conclusion Results indicate that hypoxia may cause pulmonary artery pressure change and right ventricle has compensatory reaction to hypoxic pulmonary hypertension. Dynamic changes of plasma AM, CGRP and CNP concentrations can be regarded as indexes for condition of illness.

SELECTION OF CITATIONS
SEARCH DETAIL